Exhaust pipe or odour-removal system for the hotel kitchen

The rules on the smell of a hotel kitchen are in the municipality’s environmental plan.

· Editors Hotel Magazine

A steel exhaust pipe on a flat roof against a pale sky.
Editorial image

On the roof of a hospitality building there is often a pipe through which the kitchen air goes outside. The Information Point for the Living Environment (IPLO) describes the choice a hospitality business has when it is set up or when its activity changes: an exhaust pipe that comes out 2 metres above the roof within 25 metres of buildings, or an odour-removal system. If a building stands within 25 metres of the hospitality business, the highest point of that building counts, also when it concerns the business’s own building. The aim is better dispersion of the smell. Royal Hospitality Netherlands (KHN) also names an exhaust pipe that is high enough compared with the surrounding buildings, and writes that it must discharge the escaping air as vertically as possible.

There is also the matter of grease. At hospitality businesses that grill, deep-fry or bake in oil or fat, greasy fumes are released, writes IPLO. The business must discharge those fumes through a grease-trapping filter. That does not apply to grilling with charcoal, because no greasy fumes are released then. IPLO writes that no rules on smell apply to a hospitality business that only uses kitchen appliances. A grease-trapping filter reduces part of the odour emission, but not entirely, and an odour-removal system with ionisation or ozone injection does not always have to lead to less odour nuisance. Practice has to show that.

A steel extractor hood with a metal filter above an empty cooker.
Editorial image

Who sets those rules is the municipality. KHN names the Environment and Living Environment Activities Decree and the Living Environment Quality Decree as the basis and writes that the exact rules are in the environmental plan. IPLO adds that the Living Environment Quality Decree contains no separate instruction rule for odour measures at hospitality businesses, so the municipality itself decides whether and which rules it includes. Since 2024 municipalities can change rules locally. If a business meets the rules and the odour load is still too high, the competent authority, usually the municipality, can issue a tailor-made decision with additional requirements.

In brief

Choice: exhaust pipe 2 metres above the roof within 25 metres of buildings, or an odour-removal system

Grilling, deep-frying and baking in oil or fat: grease-trapping filter

Grilling with charcoal is not covered

The exact rules are in the municipality’s environmental plan

Sources and image credits →